HomeMy WebLinkAbout2026-01ORDINANCE NO.2026-01
AN ORDINANCE AMENDING CHAPTER 102 (UTILITIES), ARTICLE II (FEES AND
CHARGES), SECTION 102-33, PERTAINING TO SANITARY SEWER CONNECTION
FEES, FRONTAGE CHARGES AND WASTEWATER LATERAL REPAIR AND
REPLACEMENT CHARGES, AND ARTICLE IV (WASTEWATER), DIVISION 3
(CONNECTIONS TO PUBLIC SEWERS), SECTION 102-180, PERTAINING TO
CONNECTIONS TO PUBLIC SEWERS.
BE IT ORDAINED, by the City Council of the City of Fairfax, Virginia, that Chapter
102, Article II, Section 102-33 and Article IV, Division 3, Section 102-180, be and hereby are
amended to read in their entirety as follows:
"Sec. 102-33. — Sanitary sewer connection fees, frontage charges and wastewater lateral
repair and replacement charges.
Except as provided herein, the sanitary sewer availability fees and frontage charges shall
be as set forth in the schedule of rates and levies adopted annually by the city council. Copies
of this schedule shall be kept on file in the office of the city treasurer. Where fees are based
on the number of "fixture units," the number of fixture units shall be as set forth in the
plumbing code referenced by the current edition of the Virginia Uniform Statewide Building
Code.
Multiuse premises shall be charged based on the various types of use or on the principal
use whichever results in the higher charge.
Unless otherwise stated, the type of premises and units of measurement [occupancy unit]
shall be as defined in chapter 102 [section 102-1].
(1) Availability charge. Notwithstanding the foregoing, availability charges for sanitary
sewer in special cases shall be determined by the city manager or his designees. In
such special cases, areas of consideration in calculating the availability charge shall
include, but are not limited to, typical consumption; strength of the wastewater;
comparable use data; principal uses; and number and type of fixture units to be
served. Apartments and condominium apartments shall be 80 percent of the single-
family availability charge per dwelling unit. Hotel, motel, and roominghouses shall
be 25 percent of the single-family availability charge per occupancy unit.
Where an existing single-family home is converted to sanitary sewer from a private
septic system, the availability charge will be 50 percent of the standard single-
family availability fee for sanitary sewer.
Where plumbing fixtures discharging to the sanitary sewer are added to existing
occupancies other than single family dwellings, townhouses, apartments, residential
condominiums, hotels, motels and rooming houses, the fee for the added fixtures
shall be charged at the rate for additional fixtures in the Schedule of Rates and
Levies. The number of fixture units shall be based on the edition of the plumbing
code as referenced by the Virginia Uniform Statewide Building Code.
The city manager or his designees reserves the right to determine, on an annual
basis, the maximum daily quantity of sewage when compared to the usage
determined when the availability charge was calculated. Usage in excess of the
charge of the availability charge shall require an increase in the availability charge
and at the rates at the time of the reconciliation of the availability charge.
(2) Frontage charge. The city manager or his designee shall reasonably determine the
type of premises and frontage charges for all premises when the premises does not
fall under any of the listed types.
Unless otherwise stated, the type of premises and units of measurement shall be as
defined in chapter 110 of this Code. The term "occupancy unit" means any room or
suite of rooms typically rented as a unit containing overnight sleeping
accommodations which are separate from any other such room or suite of rooms
within the same hotel, motel or roominghouse.
Where an existing single-family home is converted to sanitary sewer from a private
septic system, the frontage charge accordance with the schedule of rates and levies
shall be waived.
(3) Wastewater lateral repair and replacement charge.
Type of Premises
Measure
Amount
a. Single-family dwellings, whether detached,
Dwelling unit
$4.50 per unit per quarter
semidetached, duplex or townhouse
b. Apartments and condominium apartments
Connection
$3.00 per connection per
month
c. Hotels, motels and roominghouses
Connection
$3.00 per connection per
month
d. Commercial or industrial uses and all other
Connection
$3.00 per connection per
uses except those premises specifically set
month
forth above
Income from the wastewater lateral repair and replacement charge will be escrowed
in a separate account and used solely for eligible reimbursements for wastewater
lateral repairs and replacements managed and paid by the customer and for
administrative and other direct services provided by the utility exclusively for
wastewater lateral repairs and replacements. Eligibility is based on demonstrated
need and meeting program requirements to include substantiation of reasonable
costs and city approved installations meeting city plumbing code requirements.
Eligibility excludes root infestation, blockage removal and owner's abuse or fault.
Reimbursement shall be based on (1) 75 percent of actual payments made by the
customer up to a maximum of $5,000.00 : 6 500.00 for replacements from the
dwelling or business unit entirely to the main; (2) 25 percent of actual payments
made by the customer up to a maximum of $2,500.08 3 250.00 for repairs or
replacements only within the right-of-way; and (3) 25 percent of actual payments
made by the customer up to a maximum of $2,500.00 $3,250.00 for repairs or
replacements only within the private property and only for the entire length. Repairs
within the private property are not eligible. Reimbursement for replacement of
laterals shall be a one-time obligation of the utility. Repairs within the right-of-way
are eligible for more than one repair when no fault of the customer.
"Sec. 102-180. — Connections to public sewers.
(a) Tapping public sewers. All labor and material necessary for installing connections
between building and sewer mains, including those portions located within the rights -of -
way of public or private streets, shall be furnished by the owners of such building at their
cost and expense. All necessary work shall be done by a plumber registered in the city.
Connections to sewer mains shall be made through existing manufactured tees previously
installed or the connection shall be made by means of inserting an approved saddle and
affixing it to the main in a method approved by the code official. Cutting into the pipe for
branches will be permitted only with a commercially manufactured tapping or drilling
machine. Whenever it is necessary to tap the sewer main, it shall be tapped on a 45-degree
angle unless permission is otherwise granted by the administrative authority. The pipe
shall be completely uncovered, the excavation shall be free of all water and shoring shall
be installed if necessary. No sewer main shall be cut for a tap or any other purpose except
during the presence of and under the supervision of a plumbing inspector. The division of
building and fire code administration shall be notified at least 24 hours before a tap is
desired. Before the tap can be made, the owner of the premises shall have made
application to the director of public works aof uti i*ies- for the connection and
paid all necessary charges. The owner of the premises or permit applicant is responsible
for 12roviding the number of structures and units (if applicable) that previously discharged
to the sanitaU Sewer to earn credit on any availability fees. To earn credit, the owner of
the premises or applicant must provide documentation or plans when the plumbing permit
application is submitted to the division of building and fire code administration. If the
owner of the premises or applicant fails to provide such documentation or plans. the
dwatment of public works will charge availability fees in full. At the time the tap is
made, a section of the connection to be installed adjacent to the sewer main shall be
assembled and available for insertion into the saddle. Immediately after the saddle and the
section of building sewer have been fastened in place, it shall be supported with cement,
covered with heavy paper and then covered to a depth of two or more feet with dry dirt.
The tap must be protected from water while the cement is green and if the plumbing
inspector directs, pumps must be used to keep water from the tap until the cement is hard.
Test tees shall be located not closer than five feet from the sewer saddle and the pipe
between the test tee and saddle shall be of approved material. After the tap is made, the
sewer must be completed and inspected in the shortest time possible. Trenches must not
be left open longer than a reasonable length of time to complete work and sewers shall be
protected at all times from damage by water and mud. Sufficient backfill shall be placed
over the pipe by hand to prevent damage when filling the trench and that portion of the
trench in the street shall be tamped in six-inch layers, each compacted to 95 percent
density until backfill is completed. Any additional requirement of the city shall be carried
out.
In the subdivisions where the sewer mains are being installed by the developer, the
developer may also install a spur extending from the sewer main to one foot beyond the
property line for each lot. In cases where spurs would terminate under sidewalks or utilities, a
variance may be granted by the authority having jurisdiction. This extension is to receive the
building sewer for each lot.
In apartment developments, shopping centers or on other types of easements, the
developer may extend a spur not more than one length of pipe from the public sewer. This
extension shall not exceed ten feet.
Such extensions are to be shown on the sewer plans submitted to and approved by the
director of public works. These extensions are to be installed in the exact location shown on
the plan, under the supervision of a registered master plumber, and with a permit issued for
each spur. These spurs shall be constructed of the approved material, properly plugged at the
end of the spur and laid to the grades required by this article. The spur shall be inspected by a
plumbing inspector.
After a building is connected through a spur to the sanitary or storm sewer, the spur shall
become a part of the building sewer and the owner of the premises shall be responsible for the
operation and maintenance of the entire building sewer between the building and the street
sewer as set forth in subsection (f) of this section.
(b) Broken or damaged sewer main. If a section of the sewer main is broken or damaged
during the process of tapping, the plumber shall immediately replace or repair the broken
section under the direction of a plumbing inspector pursuant to specifications
promulgated by the director of public works and at the expense of the plumber. A
plumbing inspector shall notify the director of public works as soon as possible.
(c) Building sewers to trunk lines. Trunk lines may not be tapped, but where available and
with the approval of the director of public work of utilities building sewer
may enter a trunk line manhole and a satisfactory bench and invert built at the expense of
the plumber. If no manhole is available, permission to construct a new manhole must be
secured from the director of public works and it must be built at the plumber's expense
and under the direction of the director of public works.
(d) Building sewers entering manhole. When permission is given by the director of public
works, house connections may enter a manhole on the top of the bench and a satisfactory
invert shall be built by the plumber under the direction of a plumbing inspector. The
manhole shall be made watertight where the building sewer enters. The channel in the
manhole for the entering building sewer shall be made to the full size of the pipe it
connects. It shall have a smooth rounded bottom. The benches shall be brought up to the
full height of the channel and drain toward the main channel. Channels shall curve
toward the flow of the sewer main.
(e) Protection of building sewer. Where there is danger of surface water or mud entering the
building sewer, the pipe must be plugged.
3
(f) Ownership of building sewer. The ownership of connections between buildings and
sewer mains, including those portions located within the rights -of -way of public or
private streets, shall be vested in the owners of such premises and the city shall not be
responsible for the operation and maintenance of such connections.
(g) Size of tap permitted. No eight -inch sanitary sewer shall be tapped for a building sewer
larger than five inches unless approved by the director of public works. "
This amendments contained within this ordinance shall become effective as provided by law.
Enacted this 13' day of January, 2026.
ATTEST:
k 1.
,I, JL&
City Clev j
VOTE:
Councilmember Amos
Aye
Councilmember Bates
Aye
Councilmember Hall
Aye
Councilmember Hardy -Chandler
Aye
Councilmember McQuillen
Aye
Councilmember Peterson
Aye
�f.
Mayor
i� /y/zc'
Date
4